Paradyne 3821PLUS manual Pause Time S8 No Answer Timeout Line Crnt Disc S65

Models: 3821PLUS

1 175
Download 175 pages 9.59 Kb
Page 151
Image 151

Country-Specific Configuration Options

Table H-1

(2 of 5)

Configuration Options by Country (A through M)

Strap Description

ª,º Pause Time (S8)

No Answer Timeout

(S7)

Line Crnt Disc (S65)

No Carrier Disc (S10)

V= Valid

I = Invalid

F= Factory Default

 

DCP Choice

AT Command

Australia

Austria

Belgium

Cyprus

Czechia

Denmark

Eire

Finland

France

Germany

Israel

Italy

Japan

 

2 sec

S8=2

F

F

F

F

F

F

F

F

F

F

F

F

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 sec to

S8=4 to S8=20

V

V

V

V

V

V

V

V

V

V

V

V

V

 

 

20 sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ð

S8=0

V

V

V

V

V

V

V

V

V

V

V

V

V

 

 

30 sec

S7=30

V

I

I

V

I

I

V

V

I

I

I

I

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ð

S7=40

V

I

I

V

I

I

F

V

I

I

I

I

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45 sec

S7=45

F

I

F

F

I

I

I

F

I

I

I

I

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60 sec

S7=60

I

F

V

V

F

F

I

V

I

F

F

F

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ð

S7=90

I

V

I

V

I

I

I

I

I

I

I

I

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120 sec

S7=120

I

I

I

I

I

I

I

I

I

I

I

I

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ð

S7=135

I

I

I

I

I

I

I

I

F

I

I

I

I

 

 

Enab (>8 msec)

S65=0

I

I

I

I

I

I

I

I

I

I

I

I

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enab (>90 msec)

S65=1

F

F

F

F

F

F

F

F

I

F

F

F

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disable

S65=2

V

V

V

V

V

V

V

V

F

V

V

V

V

 

 

2 sec

S10=20

F

F

F

F

F

F

F

F

F

F

F

F

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 sec

S10=50

V

V

V

V

V

V

V

V

V

V

V

V

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 sec

S10=100

V

V

V

V

V

V

V

V

V

V

V

V

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20 sec

S10=200

V

V

I

V

I

I

V

V

V

I

V

V

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disable

S10=255

V

I

I

I

I

I

I

I

I

I

V

I

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3821-A2-GB20-40

January 1999

H-3