Chapter 9. Dial Plan Terminal Menu
»»Data 56K, Data 64K, Rejects outgoing calls based on call type. For example, setting the reject
Audio, Speech | number to $, Digital 56/64 to enabled, and Audio and Speech to disabled, |
| rejects all digital calls while not rejecting analog calls. |
» Ifce Config
>GLOBAL PARAM
»End of Number Timeout
This list may remain blank if the Accept List meets desired filtering. The Call Reject list takes precedence over the Call Accept list.
Sets configuration parameters for the endpoint. These parameters vary by the type of port selected. For detailed information on the interface configu- ration, see Interface Configurations on page
Sets ATLAS options which apply to all switched operations, both incoming and outgoing calls.
Write security: 3; Read security: 5
Sets the length of time ATLAS waits before assuming the outgoing dialed number is complete. The default value is six seconds. This timeout will only be invoked if the dialed number does not match one of the patterns set in the Number Complete Template menu (see Nbr Complete Templates below).
» Area Code | Write security: 3; Read security: 5 |
| The local area code. Use for sending caller ID to the Network. |
» Nbr Complete | Write security: 1; Read security: 5 |
Templates | Sets completed number patterns for outgoing calls so that ATLAS recog- |
| nizes when the phone number is complete. For example, a local number |
| will be 7 digits long while a long distance (1+ #) will be 11 digits long. The |
| ATLAS defaults cover almost any installation, and these templates should |
| not require any additional user input except for unusual circumstances. |
| The template allows the use of the following wild card inputs to define |
| numbers: |
X = Any single digit
N= Any single digit
911 = This specific number
[1,2,3...] = A single digit in this group
ATLAS 810PLUS User Manual |