Chapter 6. Terminal Menu and System Control

»Chain Port Rx Bytes

»Chain Port Overrun Errs

»Chain Port Framing Errs

»Clear Chain Port Countrs

>SYSTEM CONFIG

Read security: 5

Displays the number of received data bytes.

Read security: 5

Displays the number of overrun errors.

Read security: 5

Displays the number of received framing errors.

Clears all chain port counters. Press Y to activate command.

The System Config menu allows you to set up the ATLAS operational con- figuration. Figure 6-3shows the items included in this menu.

Figure 6-3. System Configuration Menu

»Primary Timing Source

»Backup Timing Source

Write security: 3; Read security: 5

Selects the primary timing source. You can select either INTERNAL or a port from one of the installed modules.

Write security: 3; Read security: 5

Selects the secondary timing source. You can select either INTERNAL or a port from one of the installed modules. ATLAS 810PLUS uses the backup timing source if the primary timing source goes into alarm. The Backup Timing Source should be different from the Primary Timing Source.