Appendix A. System Event Logging
|
| Table |
|
|
|
Event | Category | Console Log String |
|
|
|
ATLAS configuration file loaded into the | Critical | System Configuration Uploaded |
system and activated |
|
|
|
|
|
Console login failurea | Minor | Login Failure |
Internal system temperature has returned to | Critical | Internal Temperature Warning Cleared |
normal |
|
|
|
|
|
Internal system temperature is too high | Critical | Internal Temperature Warning |
|
|
|
Module found | Info | Module Found |
|
|
|
Module removed or not responding | Warning | Module Not Responding |
|
|
|
Primary power supply is present but is not | Critical | Main Power Supply Failure |
operating properly |
|
|
|
|
|
SNMP authentication failureb | Info | SNMP Authentication Failure |
System cold startc | Normal | Cold |
The backup power supply is operating | Critical | Backup Power Supply Failure Cleared |
properly or has been removed |
|
|
|
|
|
The backup power supply is present but is | Critical | Backup Power Supply Failure |
not operating properly |
|
|
|
|
|
The primary power supply is operating | Critical | Main Power Supply Failure Cleared |
properly or has been removed |
|
|
|
|
|
a.Three consecutive login attempts were attempted and failed.
b.Generated if the ATLAS receives an SNMP request from an SNMP manager defined in the ATLAS SNMP commu- nities list but with a community name that does not match the community name defined in the SNMP communities list.
c.Generated five seconds after the completion of system initialization.
|
| Table |
|
|
|
Event | Category | Console Log String |
|
|
|
Call rejecteda | Warning | <number> rejected: No such number |
Call rejectedb | Normal | <number> rejected: Outgoing reject list |
Call rejectedc | Normal | <number> rejected: Busy |
Call successfully routed | Normal | <number> accepted: <slot> <port> |
|
|
|
a.No such number in dial plan.
b.Number is on outgoing reject list.
c.All endpoints busy.
ATLAS 810PLUS User Manual |