ADTRAN 810 Plus manual Terminal Menu and System Control

Models: 810 Plus

1 188
Download 188 pages 59 Kb
Page 63
Image 63

Chapter 6. Terminal Menu and System Control

Current CSS Thrsh

Current PCV Thrsh (D4)

Current PCV Thrsh (ESF)

Current LES Thrsh

Current LCV Thrsh

»»DS1 Total Current Perf Threshold

Total ES Thrsh

Total SES Thrsh

Total SEFS Thrsh

Total UAS Thrsh

Total CSS Thrsh

Total PCV Thrsh (D4)

Total PCV Thrsh (ESF)

The DS1 performance monitor Threshold Value for the Current 15 minute Controlled Slip Seconds (SES) parameter. The default value is 1 for an ap- proximate BER level of 10E-5.

The DS1 performance monitor Threshold Value for the Current 15 minute Path Code Violation (PCV) parameter, when the Line Type is Super Frame (AT&T D4 format) DS1. The default value is 72 Framing errors for an ap- proximate BER level of 10E-5.

The DS1 performance monitor Threshold Value for the Current 15 minute Path Code Violations (PCV) parameter, when the Line Type is Extended Su- per Frame (ESF) DS1. The default value is 13,296 CRC errors for an approx- imate BER level of 10E-5.

The DS1 performance monitor Threshold Value for the Current 15 minute Line Errored Seconds (LES) parameter. The default value is 65 for an approx- imate BER level of 10E-5.

The DS1 performance monitor Threshold Value for the Current 15 minute Line Code Violations (LCV) parameter. The default value is 13,340 for an ap- proximate BER level of 10E-5.

Defines performance threshold values for DS1 Line and Path statistics. If a statistic value exceeds its threshold value, then the corresponding Alert Trap will be sent if the alert event is armed and Alert Taps are enabled. These threshold apply to all DS1 interfaces in the system.

The DS1 performance monitor Threshold Value for the Total Errored Sec- onds (ES) parameter. The default value is 648 for an approximate BER level of 10E-5.

The DS1 performance monitor Threshold Value for the Total Severely Er- rored Seconds (SES) parameter. The default value is 100 for an approximate BER level of 10E-5.

The DS1 performance monitor Threshold Value for the Total Severely Er- rored Framing Seconds (SEFS) parameter. The default value is 17 for an ap- proximate BER level of 10E-5.

The DS1 performance monitor Threshold Value for the Total Unavailable Seconds (UAS) parameter. The default value is 10 for an approximate BER level of 10E-5.

The DS1 performance monitor Threshold Value for the Total Controlled Slip Seconds (SES) parameter. The default value is 4 for an approximate BER lev- el of 10E-5.

The DS1 performance monitor Threshold Value for the Total Path Code Vio- lations (PCV) parameter, when the Line Type is Super Frame (AT&T D4 for- mat) DS1. The default value is 691 Framing Errors for an approximate BER level of 10E-5.

The DS1 performance monitor Threshold Value for the Total Path Code Vio- lations (PCV) parameter, when the Line Type is Extended Super Frame

61200266L1-1

ATLAS 810PLUS User Manual

6-11

Page 63
Image 63
ADTRAN 810 Plus manual Terminal Menu and System Control