ADTRAN 810 Plus manual » State, » Status, » Rev

Models: 810 Plus

1 188
Download 188 pages 59 Kb
Page 79
Image 79

Chapter 7. Modules Terminal Menu

» State

Read security:5

 

 

Displays whether the module is online of offline. Even though a module is

 

physically installed, it must be marked Online for it to be considered an

 

available resource. This parameter allows an installed module to be marked

 

Offline, which may be useful in system troubleshooting. If you choose

 

Offline, the module will not be in alarm condition, but will display Offline.

 

 

 

 

 

Once a module is installed, the state must be set to Online in

 

 

order for the ATLAS to utilize the module for any data bandwidth.

» Status

 

 

Read security:5

 

 

Displays status information on the ATLAS 810PLUS T1/PRI ports and other

 

installed modules as follows:

 

Online

The module is enabled and is responding to the system

 

 

controller’s status polls. This is the normal response of the

 

 

system.

 

No Response

The module is enabled but is not responding to the sys-

 

 

tem controller’s status polls. This response indicates a

 

 

problem in the system or that the module is not installed.

 

Empty

The system controller has not detected the presence of a

 

 

module in the system, nor has a module been manually

 

 

enabled for this option slot.

 

Offline

The module is installed but has been taken Offline by a

 

 

user. The module is still responding to controller polls.

 

Offline/No

The module is installed but has been taken Offline by a

 

Response:

user. The module is not responding to polls.

 

Not Supported

The module is not supported by the current system con-

 

 

figuration.

» Rev

Read security:5

 

 

Displays the hardware revision of the ATLAS 810PLUS.

61200266L1-1

ATLAS 810PLUS User Manual

7-3