ADTRAN 810 Plus »» Performance 15 Min, Port Name, Frame, Code, Tx Yellow, Tx PRMs, LB Accept

Models: 810 Plus

1 188
Download 188 pages 59 Kb
Page 82
Image 82

Chapter 7. Modules Terminal Menu

LCV

Line Code Violations.

PCV

Path Code Violations.

LES

Line Errored Seconds.

»» Performance: 15 Min

Write security:3; Read security:5

 

In the Performance 15 min. menu, the performance data for the previous 15

 

minute window is stored. Refer to Performance: Curr on page 7-5for a

 

detailed description.

»»Performance: 24 Hr. Write security:3; Read security:5

 

In the Performance 24 hr. menu, the performance data for the previous 24

 

hour window is stored. Refer to Performance: Curr on page 7-5for a detailed

 

description.

»» Configuration

All of these configurable parameters depend on whether the port is connect-

 

ed to a Primary Rate ISDN circuit or a Channelized T1 circuit—dedicated or

 

switched.

Prt

Read security:5

 

Identifies the port number.

Port Name

Write security:3; Read security:5

 

Accepts any alphanumeric name up to 16 characters long to uniquely iden-

 

tify each port.

Frame

Write security:2; Read security:5

 

Matches the frame format of the circuit to which it is connected (available

 

from the network supplier).

Code

Write security:2; Read security:5

 

Matches the line code of the circuit to which it is connected (available from

 

the network supplier).

Tx Yellow

Write security:3; Read security:5

 

(Auto Tx Yellow Alarm) Enables and disables the transmitting of yellow

 

alarms.

Tx PRMs

Write security:3; Read security:5

 

(Transmit PRMs) Enables and disables the sending of PRM data on the facil-

 

ity data link (FDL). The PRM data continues to be collected even if Tx PRM

 

is disabled (possible only with ESF format).

LBO

Write security:2; Read security:5

 

(Line Build Out) Depends on whether the circuit is provisioned for DS1 by

 

the telephone company.

LB Accept

Write security:3; Read security:5

 

(Loopback Accept) Sets unit to accept or reject the in-band loop up and loop

 

down codes as defined in ANSI T1.403. This is a line loopback.

7-6

ATLAS 810PLUS User Manual

61200266L1-1

Page 82
Image 82
ADTRAN 810 Plus manual »» Performance 15 Min, Port Name, Frame, Code, Tx Yellow, Tx PRMs, LB Accept