ADTRAN 810 Plus manual »» Save Config, Remotely, Server in Tftp Server IP Address, »» Selftest Run

Models: 810 Plus

1 188
Download 188 pages 59 Kb
Page 72
Image 72

Chapter 6. Terminal Menu and System Control

»» Save Config

Write security: 3; Read security: 5

Remotely

Saves the configuration file specified in TFTP Server Filename to the

 

server identified in TFTP Server IP Address. To start this command, enter

 

Y to begin or enter N to cancel.

Before using this command, you must have identified a valid TFTP

Server in TFTP Server IP Address.

»System Utilization Write security: 0; Read security: 0

Displays statistics related to the ATLAS internal operating system. Please check with ADTRAN Technical Support before attempting to use this menu.

»System Selftest Write security: 3; Read security: 5

Initiates a system self-test. The self-test consists of memory tests and data integrity tests for each installed module.

Self-tests disrupt data flow.

»» Selftest Run

Write security: 3; Read security: 5

 

Runs system-wide selftest, Memory, Flash, Bootrom, and Port Tests. These

 

tests are disruptive to all data traffic; therefore, do not run these tests on a

 

unit unless data interruptions are acceptable. To confirm self-test activation,

 

press Y; to cancel the self-test press N.

»» Current Test Status

Security level: 3; Read security 5

 

Indicates a system self-test. The self-test consists of memory tests and data

 

integrity tests for each installed module.

»»Current Slot/Port Displays slot and port of the subsystem currently being tested.

6-20

ATLAS 810PLUS User Manual

61200266L1-1

Page 72
Image 72
ADTRAN 810 Plus manual »» Save Config, Remotely, Server in Tftp Server IP Address, »» Selftest Run, »» Current Test Status