Chapter 9. Dial Plan Terminal Menu
»»Outgoing Caller ID Write Security: 3 Read Security: 5
Allows the user to insert a called ID to outgoing calls (coming in from attached User equipment). If set to 6HQGýDVý3URYLGHG, then ATLAS will for- ward whatever ID it receives (including none). If set to 6XEVWLWXWHýLIýQRWý SUHVHQW, then ATLAS inserts a
»ID Presentation Defines control information for the presentation of Caller ID (3UHVHQWDWLRQý $OORZHGâý3UHVHQWDWLRQý5HVWULFWHGâý1XPEHUý1RWý$YDLODEOH).
» ID Number | Value for Caller ID to be sent to the Network (i.e., 256 963 8020). |
» Source ID | Simplifies the creation of a Dial Plan in applications where the criterion for |
| switching calls to a certain endpoint is a function of which endpoint origi- |
| nated the call. |
| • Default value = 0. The default ID for all endpoints is 0 and all accept # s |
| is 0. With default values, all calls are routed based only on dialed num- |
| ber. |
| • Multiple endpoints can have the same Source ID. |
| • When creating the Call Accept list, specify a Source ID(s) as well as a di- |
| aled number or range of dialed numbers to accept. |
| For example, an application requires that all calls originating from Port 1 of |
| the Quad T1/PRI module in Slot 1 be switched to Port 4 of that same mod- |
| ule. Assign a unique Source ID (e.g., 7) to Port 1 of the module, and then |
| configure Port 4 to only accept calls from that unique Source ID (7). |
»» Swap ANI/DNIS | Swaps the ANI and DNIS numbers prior to being forwarded to the attached |
| user equipment. ANI (Automatic Number Identification) is the billing |
| number of the calling party, and DNIS (Dialed Number Identification Ser- |
| vice) is the called party number. |
|
|
| This swap occurs after the ATLAS switchboard has routed the call. |
| The accept number in the Dial Plan must use the number in the |
| DNIS position prior to swapping. |
|
|
Quad T1/PRI Module (User Termination/NFAS)
| When you are working in the User Termination section of the Dial Plan |
| menu, Slot is defined as a T1/PRI module, and Sig is set to NFAS, the fol- |
| lowing configuration menu is available (in addition to the standard User |
| Termination/PRI configuration menus and options): |
» Secondary | Write security: 3; Read security: 5 |
Interfaces | Defines the additional PRI interfaces controlled by the |
| endpoint. |
» Slot, Port | Write security: 3; Read security: 5 |
| Defines the slot and port in which the additional interface terminates. |
ATLAS 810PLUS User Manual |