ber of the trap destination list when accumulated error statistics exceed these threshold values. Table 11-4describes the alert traps supported by ATLAS 810PLUS for events that have occurred in the last 15-minute interval.

 

 

Table 11-4. DS1 Current Alert SNMP Traps

 

 

 

Current Alert

Severity

Description

 

 

 

 

 

 

adATLAS800CurrentES

Warning

The current interval errored second threshold has

 

 

been exceeded.

 

 

 

adATLAS800CurrentSES

Warning

The current interval severely errored second

 

 

threshold has been exceeded.

 

 

 

adATLAS800CurrentSEFS

Warning

The current interval severely errored framing second

 

 

threshold has been exceeded.

 

 

 

adATLAS800CurrentUAS

Major

The current interval is unavailable.

 

 

 

adATLAS800CurrentCSS

Warning

The current interval path code violations have been

 

 

exceeded.

 

 

 

adATLAS800CurrentLES

Warning

The current interval line errored second threshold has

 

 

been exceeded.

 

 

 

adATLAS800CurrentCV

Warning

The current interval line code violation threshold has

 

 

been exceeded.

 

 

 

When one of the Current Alert thresholds is exceeded, the corresponding event bit is set to 1 in the adDS1CurrentAlert variable in the DS1 alert table. When enabled, ATLAS 810PLUS sends alert traps to each member of the trap destination list upon detecting status bit changes in adDS1CurrentAlert. If you have previously set the corresponding enable bit = 1 in the adDS1CurrentArm variable and adDS1AlertEnable = On, then

ATLAS 810PLUS sends an alert trap message. A single alert trap message

may report multiple event changes. ATLAS 810PLUS clears the event bits af- ter sending the trap message or sending the response to a Get request for the

adDS1CurrentAlert variable. ATLAS 810PLUS clears the Current Alert values at the beginning of a new 15-minute interval. Total Alert values are cleared at the beginning of a new 24-hour interval.

Table 11-5shows the Total Alert Traps, which describe events that have oc- curred in the last 24-hour interval.