Chapter 9. Dial Plan Terminal Menu

»»Outgoing Number Write Security: 3 Read Security: 5

Conversion

Defines the rules for converting as-dialed numbers into ISDN number type

 

and plan.

As dialed

Send digits provided as unknown number type.

ISDN - National pref

Convert to ISDN type, using the 10-digit national form if possible.

ISDN - Subscriber

Convert to ISDN type, using the 7-digit subscriber form if possible.

pref

 

ISDN - National

Send digits provided as National Number Type, DMS Reserved Numbering

DMS Reserved pref

Plan.

 

 

 

When a 4ESS is configured, many installations will require the

 

national form where possible; this may also be the preferred form

 

in 10-digit calling areas.

 

 

»» Strip MSD

Write Security: 3 Read Security: 5

 

Strips a selected quantity of the Most Significant Digits (MSD) of a dialed

 

number prior to being forwarded out of the port. For example, a Network

 

port set to accept all calls beginning with 9 (9$) and Strip MSD set to 1,

 

sends all digits toward the Network except the leading 9.

 

 

 

Strip MSD does not affect the Call Accept criteria. All of the

 

digits (including the MSDs that are subsequently stripped) are used

 

as Accept criteria.

 

 

»»Netwrk Spec. Fac.- Write Security: 3 Read Security: 5

Voice

(Network Specific Facility - Voice) Defines specific facility IEs to send to the

 

Network. Use this option if the customer has subscribed to a network spe-

 

cific facility service such as AT&T Megacom service. The facility request

 

sent can be different for voice calls versus data calls. A setting of 1RUPDO

 

indicates no special facilities have been subscribed.

»»Netwrk Spec.-Fac.Write Security: 3 Read Security: 5

Data

(Network Specific Facility - Data) Defines specific facility IEs to send to the

 

Network. Use this option if the customer has subscribed to a network spe-

 

cific facility service such as AT&T Megacom service. The facility request

 

sent can be different for voice calls versus data calls. A setting of 1RUPDO

 

indicates no special facilities have been subscribed.

»» Called Digits

Write security: 2; Read security: 5

Transferred

Defines the number of digits to expect (choose from 1RQHñý7KUHHñý)RXUñ and

 

$OO). The default is All and would almost always be correct. If less than All

 

digits are sent, then the prefix is defined below. Use this option for PRI

 