Chapter 11. SNMP Management

 

 

 

Table 11-5. Total Alert Traps

 

 

 

 

Total Alert

 

Severity

Description

 

 

 

 

 

 

 

 

adATLAS800TotalES

 

Warning

The total interval errored second threshold has been

 

 

 

exceeded.

 

 

 

 

adATLAS800TotalSES

 

Warning

The total interval severely errored second threshold has

 

 

 

been exceeded.

 

 

 

 

adATLAS800TotalSEFS

 

Warning

The total interval severely errored framing second threshold

 

 

 

has been exceeded.

 

 

 

 

adATLAS800TotalUAS

 

Major

The total interval unavailable second threshold has been

 

 

 

exceeded.

 

 

 

 

adATLAS800TotalCSS

 

Warning

The total interval controlled slip second threshold has been

 

 

 

exceeded.

 

 

 

 

adATLAS800TotalPCV

 

Warning

The total interval path code violations has been exceeded.

 

 

 

 

adATLAS800TotalLES

 

Warning

The total interval line errored second threshold has been

 

 

 

exceeded.

 

 

 

 

adATLAS800TotalLCV

 

Warning

The total interval line code violation threshold has been

 

 

 

exceeded.

 

 

 

 

 

When one of the Total Alert thresholds is exceeded, the corresponding event

 

bit is set to 1 in the adDS1TotalAlert variable in the DS1 alert table. When en-

 

abled, ATLAS 810PLUS sends alert traps to each member of the trap destina-

 

tion list upon detecting status bit changes in adDS1TotalAlert. If you have

 

previously set the corresponding enable bit = 1 in the adDS1TotalArm vari-

 

able and adDS1AlertEnable = On, then ATLAS 810PLUS sends an alarm trap

 

message. A single alert trap message may report multiple event changes.

 

ATLAS 810PLUS clears the event bits after sending the trap message or send-

 

ing the response to a Get request for the adDS1TotalAlert variable.

 

Current Alert and Total Alert described above are Near End events.

 

ATLAS 810PLUS also supports Current Alert and Total Alert for the Far End.

 

Far End alert traps are generated upon status bit changes in

 

adDS1FarCurrentAlert for Current Alerts and adDS1FarTotalAlert for Total

 

Alerts. Current and Total Far End Alerts can be disabled by setting the cor-

 

responding enable bit = 0 in the adDS1FarCurrentArm and

 

adDS1FarTotalArm variables, respectively. Far End alert traps can also be

 

disabled by setting adDS1AlertEnable = Off.