SDCP Menus

Status Branch

The Status branch of the Top-Level menu allows you to view the current status of the dial or leased-line connection, the DTE interface, and the identity (for example, serial number and model number) of your equipment. The selections under Status are:

VF

Identity

DTE

SDC

Options

Record

To access Status from the Top-Level menu, press the key until Status appears. Select Status.

(Modem Status)

MDMA mdmb mdmc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Call_Setup

 

 

Test

 

Configure

 

Control

 

Remote

 

Security

Status

VF

Identity

DTE

Options Record

 

 

 

 

 

 

 

 

SigQual

Ser#

LSD

Display

RcvLev

Mod #

DTR

Clear

Sig/Noise

FRev

DSR

 

 

NearEcho

HPt#

Tst

 

 

FarEcho

FPt#

TXD

 

 

FarEchDel

Country

RXD

 

 

EchoFreqOff

RTS

98-14844-01

 

 

 

 

CTS

 

 

 

 

 

 

VF

VF displays the condition of the dial or leased-line connection.

To access VF from the Status branch, press F1 to select VF.

The modem's signal quality is displayed on the LCD's

bottom line. Press the key to scroll and view the receive signal level, signal-to-noise ratio, near end echo, far end echo delay, and echo frequency offset. Values

displayed are approximations that may be affected by the combination of impairments on the line.

NOTE

SigQual, NearEcho, FarEcho, FarEchDel, and EchoFreqOff values appear only for V.34, V.32terbo, V.32bis, and V.32 modulations.

SigQual

Signal Quality indicates the

 

condition of the VF line.

 

Possible values are Excelent

 

(Excellent), Good, Fair, Poor,

 

or No Signal.

RcvLev

Receive Signal Level

 

indicates, in decibels

 

referenced to one milliwatt

 

(dBm), the actual strength of

 

the incoming signal.

Sig/Noise

Signal-to-Noise Ratio

 

indicates, in decibels, the

 

receive signal strength relative

 

to noise on the line.

NearEcho

Near End Echo displays the

 

signal level, in decibels

 

referenced to one milliwatt

 

(dBm), of that portion of the

 

transmit signal which has been

 

echoed back by the local line

 

termination.

FarEcho

Far End Echo displays the

 

signal level, in decibels

 

referenced to one milliwatt

 

(dBm), of that portion of the

 

transmit signal which has been

 

echoed back by the remote

 

line termination.

FarEchDel

Far End Echo Delay indicates

 

the roundtrip delay in

 

milliseconds of the far end

 

echo.

EchoFreqOff

Echo Frequency Offset

 

indicates the frequency offset

 

of the far end echo.

To exit VF and remain in the Status branch, press the key. To exit and return to the Top-Level menu, press

the key.

3821-A2-GB20-40

January 1999

3-11

Page 37
Image 37
Paradyne 3821PLUS manual Status Branch, Identity, Options Record