Security

Security Configuration Options

The Security Configuration Options group under the Configure branch allows you to view and set dial access security parameters.

Table 7-5shows each Security configuration option as it appears on the LCD. The factory default value is shown after the colon (:) on the first line; all available selections are listed on the second line.

Table 7-5

(1 of 3)

Security Configuration Options

EntryWait_Time: 20 sec

Nxt 20 sec 10 sec 40 sec 60 sec

Entry Wait Timeout. Determines how long the answering modem waits for the originating modem to enter a VF-side password and DTE-side password.

This timer resets for each phase of access security. For example, if a VF-side password and a DTE-side password are required, then the user has 20 seconds per entry to provide the correct password.

The factory default is 20 seconds.

VF_Prompt_Type: 2nd_DialTone

Nxt 2nd_DialTone Quiet_Answer

VF Prompt Type. Determines how the answering modem requests a valid password from the originating modem for the valid password. This configuration option is only used for VF-side password entry and is not valid for DTE-side password entry.

NOTE: This configuration option only appears if the Answer Security Mode configuration option is configured for VF_&_DTE or VF_w/_DTE.

2nd Dial Tone ± Once the answering modem is off-hook, it generates a dial tone to the originating modem as a prompt for that modem's VF-side password. (Wait for Second Dial Tone is represented by a W in the dial command string.)

Quiet Answer ± Once the answering modem is off-hook, it does not send an answer tone to the originating modem. The originating modem enters its VF-side password after detecting a ring back signal followed by five seconds of silence. For this to work correctly, the Auto Answer Ring # configuration option in the answering modem must be set to 2 rings or greater. (Wait for Quiet Answer is represented by an @ in the dial command string.)

The factory default is 2nd_DialTone.

#DTE_PW_Tries: 1 Nxt 1 2 3 4 5

Number of DTE Password Tries. Determines the number of attempts an originating user has to enter a valid DTE-side password. If the password entered does not match a value in the answering modem's Password Table, then the modem will issue the password prompt again (provided that the number of tries is set to a value greater than 1). This will continue until the correct password is entered by the originating user or the number of tries allowed is met.

The factory default is 1.

3821-A2-GB20-40

January 1999

7-9