Paradyne 3821PLUS manual S4 ± Line Feed Character, S5 ± Backspace Character, S6 ± Blind Dial Pause

Models: 3821PLUS

1 175
Download 175 pages 9.59 Kb
Page 93
Image 93

AT Commands and S-Registers

Table 4-2

(2 of 10)

3821Plus S-Registers

S4 ± Line Feed Character

Determines ASCII value used as the line feed character.

Enter a value from 0±127 for the line feed character.

Factory setting is 10 (ASCII line feed).

S5 ± Backspace Character

Determines ASCII value used as the backspace (Backspace key). This character moves the cursor to the left and erases the previous character.

Enter a value from 0±127.

Factory setting is 08 (ASCII backspace).

S6 ± Blind Dial Pause

Determines how long (in seconds) the modem waits after going off-hook before dialing a telephone number if using result code X0, X1, or X3.

Enter a value from 2±255 seconds.

The factory setting is 2 seconds.

NOTE: The default and permitted settings of this option are country-dependent. See Appendix H.

S7 ± No Answer Timeout

Determines how long (in seconds) an originating modem waits before abandoning a call when no answer tone is received.

Enter a value from 1±255 seconds.

The factory setting is 45 seconds.

NOTE: The default and permitted settings of this option are country-dependent. See Appendix H.

S8 ± ``,º Pause Time for the Dial Modifier

Determines how long (in seconds) the modem pauses when it encounters a comma (,) in the Dial command string. Enter a value from 0±255 seconds.

The factory setting is 2 seconds.

NOTE: The default and permitted settings of this option are country-dependent. See Appendix H.

S10 ± No Carrier Disconnect

Determines how long (in tenths of seconds) the modem allows the carrier signal to be Off before disconnecting the call. Enter a value from 0±254 in 0.1 second increments. A value of 255 disables this register.

Factory setting is 20 (2 seconds).

NOTE: The default and permitted settings of this option are country-dependent. See Appendix H.

S12 ± Escape Guard Time

Sets the value (in 20-millisecond increments) for the required pause before and after the escape sequence is issued. The guard time prevents the modem from interpreting data as the escape sequence characters.

Enter a value from 0±255 in 20-millisecond increments. For example, the factory setting of 50 equals 1000 milliseconds or one second. Factory setting is 50 (1 second).

3821-A2-GB20-40

January 1999

4-17

Page 93
Image 93
Paradyne 3821PLUS manual S4 ± Line Feed Character, S5 ± Backspace Character, S6 ± Blind Dial Pause, S7 ± No Answer Timeout