MPCLII Packet Reference Manual

Status2

represents the field number within each

C- Field Number

packet. The packet header is the first

 

field and each subsequent field is

 

indicated by the field separator.

Status2

represents the parameter within the field

D- Parameter

that the error occurred. The numbering

 

begins after the field identifier.

Status2

is the error that coincides with the error

E- Error Number

numbers presented in Chapter 9, "Errors."

"FMT-1/BCH-2"

The format or batch number is returned.

n If more than one error occurred then only the most serious error will be acknowledged.

{J,"","F,B,4,6,33","FMT-1","BCH-2"}

Indicates that an error occurred on a bar code (B) field within a format (F) packet. The bar code field is the fourth (4) field in the packet. The error occurred in the sixth (6) parameter of the field. Error number 33 means the bar code density is invalid.

To clear an error, press the trigger (or E depending on your printer). An ENQ can also clear errors numbered less than 500. Once the error is corrected, a job request can be sent. The printer cannot accept another job request until the error is resolved.

7-10

Page 112
Image 112
Paxar TCMPCL2PR manual Field Number, Parameter, Error Number, B,4,6,33,FMT-1,BCH-2