MPCLII Packet Reference Manual

F5. parity

Parity.

Options:

 

0

None (default for all printers)

 

1

ODD parity

 

2

EVEN parity

F6. flow_control Flow Control. Options:

0None

1DTR (default for all printers)

2CTS

3XON/XOFF

NOTE: If you use the DOS COPY command to download your formats, set "Flow Control" to DTR (not XON/XOFF).

F6. pr_address Printer’s address. Only valid on the 9490 printer used with the Mobile Printing Station. Can be any six-byte string in the 0 to 255 decimal range enclosed by quotes. We recommend setting the printer’s address to the printable alphanumeric ASCII values (0-9; A-Z; a-z). This avoids any conflict with the control characters (ENQ, parameter separators, etc.) and is easily interpreted.

Example {I,F,3,1,0,0,1,"ABC123" p }

Uses 9600 baud, an 8-bit word length, one stop bit, no parity, DTR mode, and sets one 9490 printer’s address to ABC123.

3-14

Page 34
Image 34
Paxar TCMPCL2PR manual Example I,F,3,1,0,0,1,ABC123 p, Cts Xon/Xoff