MPCLII Packet Reference Manual

C7. bat_voltage Selects the battery voltage. Options:

015-volt battery

1 12-volt battery

n The printer’s LED does not flash after receiving this packet. To check if the battery voltage changed, print a test label. The selected printer remains active until a different printer is selected or you turn the printer off.

Example {I,C,0,0,0,0,768,1 p }

Uses the default print contrast, does not adjust the print or margin positions, prints at 2 inches per second, sets the supply width to 4 inches, and specifies a 12-volt battery.

If the only parameter you need to change is the battery voltage, make sure the printer is selected and ready to receive data. Then, send this packet:

Example {I,C,,,,,,1 p }

Keeps your previously defined print control settings and specifies a 12-volt battery.

Using Non-Addressed Mode––––––––––––––––––––––––––––––––––

In non-addressed mode, the printer uses a single communication cable and does not need to be addressed or selected before sending format and batch packets. To use a printer in non-addressed mode, you must clear the printer’s address. Make sure the printer is selected and ready to receive data. Clear the printer’s address by sending this packet:

Example {I,F,,,,,,"" p }

Keeps your previously defined communication settings and clears the printer’s address. The address becomes 000000.

Your printer is ready to operate in non-addressed mode. You can send format, batch, or any other MPCLII packets to the printer.

E-4