Paxar TCMPCL2PR manual Error Description Code

Models: TCMPCL2PR

1 217
Download 217 pages 52.55 Kb
Page 126
Image 126

MPCLII Packet Reference Manual

Error Description

Code

031Human readable option must be 0 not UPCA or EAN

1 no CD or NS

5 NS at bottom, no CD

6 CD at bottom, no NS

7 CD and NS at bottom

8 no text

See "Defining Bar Code Fields" in Chapter 4 for the bar code density chart.

032Bar code type is invalid. See "Defining Bar Code Fields" in Chapter 4 for valid options.

033Bar code density is invalid. See "Defining Bar Code Fields" in Chapter 4 for the bar code density chart.

040Line thickness is outside the range 0 to 99.

041Line origin direction must be 0, 90, 180, or 270.

042End row is invalid. Line segment or box end row is defined outside of printable area.

043End column is invalid. Line segment or box end column is defined outside of printable area.

044 Dot pattern for line or box must be "".

045Line length is defined beyond the maximum length. See "Defining Line Fields" in Chapter 4 for valid lengths.

046Line type must be S (segment) or V (vector). See "Defining Line Fields" in Chapter 4 for valid line types.

051 Imaging mode in the graphic header must be 0.

101No format corresponding to format number in batch header.

9-4

Page 126
Image 126
Paxar TCMPCL2PR manual Error Description Code