Chapter 2 - Hardware Installation

MPI-4/8 Hardware Installation for the MGC-100

The MPI-4/8 (Multi Protocol Interface) Network Interface card is inserted into the MGC-100 unit.

The MPI box may be mounted on top of the MGC-100 using mounting brackets, or on a separate 19” or 23” rack, as can be seen in Figure 2-8. When installed on a 19” rack, the MPI box can be mounted directly on the rack. When installed on a 23” rack, a mounting plate must be used. If the MGC-100 is rack mounted, there must be at least 6” free space above the MGC-100 to be able to install the MPI Box on top of the MGC unit.

MPI Box

in 19" Rack

Mounting Plate

PWR

Figure 2-10: MPI Box rack mounting options

2-16

Page 36
Image 36
Polycom DOC2237A manual MPI-4/8 Hardware Installation for the MGC-100, MPI Box rack mounting options