To install the MPI-8 Network Interface Module:

1.Slide the MPI-8 Network Interface module into a free slot in the MCU front panel.

2.Push the MPI-8 Network Interface module firmly into the Backplane, making sure it is properly seated in its slot.

3.Tighten the screws on the front panel of the MGC-50 that secure the MPI-8 Network Interface module.

To mount the MPI Box on the Rack for the MGC-50:

1.Turn OFF power to the MCU and unplug it from AC power.

2.If the MCU is rack mounted, disconnect all external cables, dismount the MCU from the rack and place it on a desktop or work table

3.Place the MPI box with is four 160-pin connectors facing the MGC-50 front panel between the two rails of the rack. Secure it to the rack with the screws supplied with the MPI Box.

PORTS

PORTS

1-4

9-12

PORTS

PORTS

5-8

13-16

4.Connect all the external cables to the MPI box:

Using the cable provided with the MPI kit, connect the 160-pin connector to Port A of the MPI-8 Network Interface front panel. Connect the other end of the cable to a (Ports 1-4) 160-pin connector of the MPI Box. Again, by doing this procedure we have utilized the MPI Box as a MPI-4.