Chapter 3 - System Architecture

The MGC Unit is made up of:

Main Control Module, located at the top left of the unit when viewed from the front

Functional Modules, located to the right of the Main Control Module when the unit is viewed from the front

Power Supply Module, located underneath the Main Control Module and Functional Modules

Input/Output cards, located behind the backplane opposite the Functional Modules.

The various modules communicate with each other via the Backplane. The Control Bus and Information Highway are implemented on the Backplane.

Figure 3-2 describes the functional block diagram of the MGC-100 components.

 

 

 

 

 

 

 

 

 

 

Backplane

Rear

 

 

 

 

 

H.323 I/O

H.323 Network I/F

 

 

 

 

 

 

 

ATM I/O

 

 

ATM Network I/F

 

 

 

NET I/O

 

 

 

 

 

 

 

 

 

 

 

 

ISDN Network I/F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MUX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MUSIC I/O

Audio

Video

Data

Main Control

Module

Front

Power Supply

Module

Figure 3-2: MGC-100 Components

3-2

Page 64
Image 64
Polycom DOC2237A manual MGC-100 Components