Promise Technology FAST TRAK100TM user manual About RAID Levels, Striping RAID

Models: FAST TRAK100TM

1 99
Download 99 pages 41 Kb
Page 71
Image 71

FastTrak100 User Manual

About RAID Levels

Striping (RAID 0)

Reads and writes sectors of data interleaved between multiple drives. When any disk member fails, it affects the entire array. Performance is better than a single drive since the workload is balanced between the array members. This array type is for high performance systems. Identical drives are recommended for performance as well as data storage efficiency. The disk array data capacity is equal to the number of drive members times the smallest member capacity. For example, one 1GB and three 1.2GB drives will form a 4GB (4 x 1GB) disk array.

Stripe Size - a value can be set from 1KB to 1024KB sector size. The size can directly affect performance. In the FastBuild BIOS, the “Desktop” default is 8KB while “Server” and “A/V Editing” are 64KB.

67

Page 71
Image 71
Promise Technology FAST TRAK100TM user manual About RAID Levels, Striping RAID