FastTrak100 User Manual

10.After rebooting, use FastBuild to re-create the array. For mirrored arrays, rebuild the mirrored array. For striped arrays, use FDISK and FORMAT after setting up the array.

Array Constantly Goes Into Critical or Offline Mode During Reboot (see “Unable to Partition or Format array” above)

Cannot Rebuild Mirrored (RAID 1) Array

(see “Unable to Partition or Format array” above)

Fatal Errors or Data Corruption Are Constantly Reported When Reading or Writing to Drive Array

(see “Unable to Partition or Format array” above)

ECC Error Reported on Rebuild

The following screen will appear if a data error is detected on either source or target drive during Rebuild if you have set the On Errors setting to “Interactive” within FastCheck’s Options Window (see page 59).

Your choices are as follows:

Abort: Halts the rebuild process. You may elect to retry at a later date.

Break ECC on Target Drive: If the error is detected on the source drive, “Break ECC on Target Drive” means that FastTrak will copy the bad data sector on to the target drive to assure that both drives are identical. If the error is detected on the target drive, FastCheck will copy the data contained in the good sector of the source drive again to the target drive.

Skip the Error Block: FastTrak100 will log the event error and continue the rebuild process. Use this setting if you want to detect the presence of

74

Page 78
Image 78
Promise Technology FAST TRAK100TM user manual ECC Error Reported on Rebuild