| A – Specifications | |
| Fabric Management | |
|
|
|
A.3 |
|
|
|
| |
Fabric Management |
|
|
Management Methods | SANbox Manager Graphical User Interface | |
| Application Programming Interface | |
| Command Line Interface | |
| ||
| SNMP | |
| FTP | |
Maintenance Connection | ||
| cable | |
Ethernet Connection | ||
Switch Agent | Allows a network management station to | |
| obtain configuration values, traffic | |
| information, and failure data pertaining to | |
| the Fibre Channels through SNMP through | |
| the Ethernet interface. | |
A.4 |
|
|
Dimensions |
|
|
Width | 17.0” (431 mm), 19 inch rack mount | |
Height | 7.0” (179 mm) (4U) | |
Depth | 27.75.” (705 mm) | |
Weight | 70 lbs (31.75 Kg) | |
A.5 |
|
|
Electrical |
|
|
Power source loading | 11.5 Amps maximum at 90 to 137 VAC | |
| 7.5 Amps maximum at 138 to 264 VAC | |
Heat Output (maximum) | 1000 Watts fully populated (8 I/O blades at | |
| ~60 Watts each) | |
Operating voltage | 90 to 264 Vac; 47 to 63 Hz | |
Circuit Protection | Internally fused |