Section 5
Diagnostics/Troubleshooting
Diagnostic information about the switch is available through the chassis LEDs, the power supply LEDs, and the Port Status LED. Diagnostic information is also available through the SANbox Manager and CLI event logs and error displays. This section describes two types of diagnostics: Power On Self Test (POST) and chassis. POST diagnostics describe the Heartbeat LED and the Port Status LED indications. Chassis diagnostics cover power supply and fan diagnostics as well as over temperature conditions. This section also describes how to use maintenance mode to recover a disabled switch.
5.1
POST Diagnostics
The switch performs a series of Power On Self Tests (POST) as part of its power- up procedure. The POST diagnostic program performs the following tests:
■Checksum tests on the boot firmware in PROM and the switch firmware in flash memory
■Internal data loopback test on all ports
■Access and integrity test on the ASIC
During the POST, the switch logs any errors encountered. Some POST errors are fatal, others are
If there are no errors, the Heartbeat LED blinks at a steady rate of once per second. If a fatal error occurs, the Heartbeat LED will show an error blink pattern. If there are
5.1.1
Heartbeat LED Blink Patterns
5.1.1.1
Normal (all pass)
If all POST diagnostics pass, the switch will go to normal operation and the Heartbeat LED will blink at a steady rate of one (1) blink per second.