B – Command Line Interface | |
Set Config Command |
threshold
Initiates a configuration session by which to generate and log alarms for selected events. The system displays each event, its thresholds, and sampling interval one line at a time and prompts you for a value. For each parameter, enter a new value or press the Enter key to accept the current value shown in brackets. These parameters must be saved in a configuration and activated before they will take effect. Refer to the ”Config Command” on page
Table B-9. Set Config Threshold Parameters
Parameter |
| Description |
|
| |
Threshold Monitoring Enabled | Master enable/disable parameter for all events. | |
| Enables (True) or disables (False - the default) the | |
| generation of all enabled event alarms. | |
CRCErrorsMonitoringEnabled | The event type enable/disable parameter. | |
DecodeErrorsMonitoringEnabled | Enables (True) or disables (False) the generation | |
ISLMonitoringEnabled | of alarms for each of the following events: | |
LoginMonitoringEnabled | ■ | CRC errors |
LogoutMonitoringEnabled | ■ | Decode errors |
LOSMonitoringEnabled | ■ | ISL connection count |
| ■ | Login errors |
| ■ | Logout errors |
| ■ | |
Rising Trigger | The event count above which a rising threshold | |
| alarm is logged. The switch will not generate | |
| another rising threshold alarm for that event until | |
| the count descends below the falling threshold | |
| and again exceeds the rising threshold. | |
Falling Trigger | The event count below which a falling threshold | |
| alarm is logged. The switch will not generate | |
| another falling threshold alarm for that event until | |
| the count exceeds the rising threshold and | |
| descends again below the falling threshold. | |
Sample Window | The period of time in seconds in which to count | |
| events. | |
|
|
|