5 – Diagnostics/Troubleshooting | |
POST Diagnostics |
5.1.1.2
Maintenance Mode Pattern
Steady illumination indicates that the switch is in maintenance mode, which returns the switch IP address to 10.0.0.1. From maintenance mode, you may reload firmware, reset the password to the factory default, and remove a corrupt configuration.
5.1.1.3
Internal Firmware Failure Blink Pattern
An internal firmware failure blink pattern is 2 blinks per second followed by a two second pause. The
1 second | 2 seconds | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5.1.1.4
Fatal Error Blink Pattern
A fatal error blink pattern is 3 blinks per second followed by a two second pause. The
1 second |
| 2 seconds |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5.1.1.5
Configuration File System Error Blink Pattern
A configuration file system error blink pattern is 4 blinks per second followed by a two second pause. The
|
| 1 second |
|
|
| 2 seconds |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
To recreate the configuration file, do the following:
1.Open a Telnet session and use the Shutdown command to close activity on the switch, then power down the switch. Refer to the ”Shutdown Command” on page