Optional memory 32 MB RAM SIMMs
»Note:
See FAQ 7191 for a list of approved SIMMs, their
manufacturers and part numbers, and the QMS products on which
they can be used. You can access QMS FAQs through the Internet
at http://www.qms.com/support/support_set.htm.
System software Softloadable; stored in Flash ROM
Voltage and
frequency US: 110/120 volts ±10% at 60 Hz ±2 Hz
Japan: 100 volts ±10% at 50/60 Hz ±2 Hz
International: 220/240 volts ±10% at 50 Hz ±2 Hz
Phase Single
Power
consumption Mode Average Maximum
Operation
Standby
Power save (engine only)
450 watts
150 watts
25 watts
1000 watts
1000 watts
Certification Energy Star compliant
Voltage Mode Average Maximum
100 volts Operation
Standby
Energy saver mode (engine
only)
4.5 amperes
1.5 amperes
0.25 amperes
10 amperes
10 amperes
110/120 volts Operation
Standby
Energy saver mode (engine
only)
3.8 amperes
1.3 amperes
0.2 amperes
8.3 amperes
8.3 amperes
220/240 volts Operation
Standby
Energy saver mode (engine
only)
2 amperes
0.7 amperes
0.1 amperes
4.5 amperes
4.5 amperes