Appendix D CM-2 Management Commands

LRS-24Installation and Operation Manual

 

 

 

 

 

 

 

 

 

D.1 Defining Dial-Up Modem Parameters

Purpose

Defines the call-out parameters for the CM-2 dial-out port. The specified call-out parameters are used by the CM-2 to build the call command that is sent to the dial-up modem.

The modem connected to the out port must be set up as follows: (For convenience, the Hayes commands required to select the specified parameters are listed in brackets.)

At least 38.4 kbps per second dial modem

Modem reports call progress result codes: OK, CONNECT, RING,

NO CARRIER, NO ANSWER, ERROR, BUSY (AT X0)

Modem sends result code to DTE (AT Q0)

No echo (AT E0)

Modem sends long form result codes (AT V1)

DTR is ignored (AT &D0)

DSR forced on (AT &S0)

Escape code character must be + (AT S2=43).

Format

DEF CALL

Procedure

To define the CM-2 call-out parameters:

Type: NODE 13 DEF CALL<Enter>.

The call-out parameters’ data form is displayed. A typical data form is shown in Table D-1.

DIAL MODEM CONFIGURATION

 

DIAL MODEM STATUS:

ACTIVE

 

COMMAND:

ATD

 

NUM OF RETRIES:

2

 

 

WAIT FOR CONNECT:

60 SECS

 

DIAL MODE:

TONE

 

PHONE NUMBER:

29

 

 

ALT NUM MODE:

YES

 

ALT NUM:

 

 

 

 

 

 

 

 

Figure D-1. Dial Modem Configuration Screen