LRS-24 Installation and Operation Manual Chapter 2 Installation and Setup
Interfaces and Connections 2-15
Table 2-5. Module CM-2 Jumper Settings
Jumpers Description Factory Settings
JP1 JP9 Sets the jumpers according to the station clock applied to the STATION CLK
connector of the LRSI-F*-CM2 interface module. The available selections are
T1 clock source (1544 kHz clock), or E1 clock source (2048 kHz clock):
T1 source: always select the balanced interface
E1 source: select either the balanced or unbalanced interface, in
accordance with the source providing the clock signal
E1 120
JP12 Selects connection of Signal Ground to Frame Ground:
GND – Connected
N.C. – Disconnected
GND
JP14 Enables Watchdog:
(see Figure 2-7)
ON
JP15 Enables Password:
Bypass – Password not required
Password – Password required
Bypass
JP16 Terminal Select:
SCC1
SCC2
SCC1
* Interface module version, for example, LRSI-F-1, LRSI-F-2, etc.
Figure 2-7 identifies the jumper settings for each clock source interface.

CM-2 Installation

To install CM-2:
1. Check that the POWER switch of the interface module is set to OFF.
2. Insert the CM-2 module in the CL slot.
3. Fasten with the two screws.

2.5 Interfaces and Connections

This section describes the installation and connections for:
PS Interface Modules
LRSI-F-CM1 Interface Module
LRSI-F-1-CM2 Interface Module
LRSI-F-2-CM2 Interface Module
LRS-24 Enclosure.