In general, if an error is detected during command evaluation, the command is not executed. Instead, the module will send an error message to the terminal. The correct command must then be sent again.

Chapter 4 Management via the CM-2 Module

LRS-24Installation and Operation Manual

 

 

Scrolling Values When a field has a limited range of values, the available values are displayed by scrolling. To scroll, bring the cursor to the desired field, and then press <F> or <U> to scroll forward, press <B> or <D> to scroll backward. Press <+> or <–>to scroll to the next or previous command, for up to 10 commands.

Command evaluation Starts only when the <Enter> key is pressed.

Errors

 

 

Execution

The command is executed only after it is validated.

 

 

Index of Commands

 

 

 

 

Table 4-1lists the set of commands recognized by the CM-2 module in

 

 

 

alphabetical order.

 

 

 

In addition to the commands listed in Table 4-1, the CM-2 module will recognize

 

 

 

commands addressed to I/O modules that can control directly the supervision

 

 

 

terminal. For information on the commands available for any particular I/O

 

 

 

module, refer to the Installation and Operation Manuals of that module.

 

 

 

Table 4-1. Terminal Command Set Index for CM-2 Module

 

 

 

 

 

 

 

Command

Function/Action

 

 

 

 

 

 

 

DEF CALL

Defines parameters for the dial-up modem.

 

 

 

 

 

 

DEF CRD

Defines modem type per slot and connection to remote site

 

 

 

 

 

 

DEF DWL

Defines operational parameters or command for Download Software version

 

 

 

 

 

 

DEF HUB

Defines parameters of CM-2 SNMP agent and general LRS-24 parameters

 

 

 

 

 

 

DEF MNG

Defines list of management stations receiving traps generated by CM-2 module

 

 

 

 

 

 

DEF OPR

Defines general management parameters of an I/O module (applicable only to modules which do not

 

 

 

support direct management by terminal or SNMP)

 

 

 

 

 

 

DEF PRM

Defines basic operational parameters of an I/O module (applicable only to modules which do not support

 

 

 

direct management by terminal or SNMP)

 

 

 

 

 

 

DEF TRM

Defines supervision terminal type

 

 

 

 

 

 

DEF TST

Performs test on an I/O module (applicable only to modules which do not support direct management by

 

 

 

terminal or SNMP)

 

 

 

 

 

 

 

DSP ALM

Displays general alarm status of LRS-24

 

 

 

 

 

 

DSP ALT

Displays module alarm status (applicable only to modules which do not support direct management by

 

 

 

terminal or SNMP)

 

 

 

 

 

 

 

DSP HUB

Displays modules installed in LRS-24

 

 

 

 

 

 

DEF CFG

Displays Auto Config screen

 

 

 

 

 

 

DEF MDL

Downloads to the modem

 

 

 

 

 

 

DSP LOG

Displays list of alarms for CM-2 module, or for a selected I/O module (applicable only to modules which

 

 

 

do not support direct management by terminal or SNMP)

 

 

 

 

 

 

DSP STT

Displays I/O module status and diagnostics (applicable only to modules which do not support direct

 

 

 

management by terminal or SNMP)

 

 

 

 

 

 

 

 

 

 

 

4-12

CM-2 Supervision Terminal Language

 

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Page 76
Image 76
RAD Data comm LRS-24 operation manual Index of Commands, Errors Execution, Command Function/Action