Appendix D CM-2 Management Commands

LRS-24Installation and Operation Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

HUB ALARM

 

 

 

 

 

 

 

 

 

 

 

POWER SUPPLY A: FAIL

 

 

 

POWER SUPPLY B: FAIL

 

 

 

CARD STATUS CHANGE: N/A

 

 

 

CURRENT MANAGEMENT: TERMINAL

 

 

 

MODEM IN SLOT 1 HAS ACTIVE ALARM

: N/A

 

MODEM IN SLOT 2 HAS ACTIVE ALARM

: N/A

 

.

 

 

 

.

 

 

 

.

 

 

 

.

 

 

 

MODEM IN SLOT 12 HAS ACTIVE ALARM

: N/A

 

STATION CLK – SQUARE LOSS SIGNAL

: YES

 

STATION CLK – AMI LOSS SIGNAL

 

: YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure D-38. Hub Alarm Screen

Display Format

The Alarm Status is displayed as a table that shows relevant information related to the LRS-24:

One line is provided for each power supply module and for I/O module slot. The line indicates whether the corresponding power supply module operates normally (OK) or failed (FAIL), and whether an active alarm condition is present in each module.

You can display the last 256 alarms using the DSP LOG command. To display the alarms of a specific module, use the DSP ALT command.

The CARD STATUS CHANGE line displays YES if a status change has been detected in the LRS-24.

The CURRENT MANAGEMENT line indicates the management system that controls the LRS-24, as shown in Table D-7.

Table D-7. Current Management Fields

Message

Description

 

 

TERMINAL

LRS-24 is managed by the terminal

 

 

NMS

LRS-24 is managed by a network management station

 

 

REMOTE MODEM

Parameters of the modules installed in the LRS-24 are

 

determined by the remote equipment connected to each

 

module

 

 

D-34 Displaying General Alarm Status