Chapter 1 Introduction

LRS-24Installation and Operation Manual

 

 

LRS-24

Supervision

Terminal

LRS-24

LRS-24

WAN

MBE

MBE

LRS-24

Management

Station

Figure 1-8. Basic Management Configuration for LRS-24 with CM-2 Modules

I/O (User) Modules

LRS-24 can be equipped with various types of input/output (I/O) modules to provide the required system functions. These include ASMi-24C, ASMi-31C, ASMi-31CQ, ASMi-50C, ASMi-450C, HTU-E1C, FOMi-40C, FOMi-E1/T1C, FOMi-E3C, FOMi-T3C, MTMi-20C, FOMi-40CD, ASM-40CD, FOMi-E1/T1/CD, ASMi-50CD, and ASMi-51CQ.

The range of modules and options available for LRS-24 is continuously expanding. Refer to the Installation and Operation Manuals of the corresponding modules for information.

1.4 Technical Specifications

Chassis

Number of

15 – Each slot is connected to an interface module slot

Characteristics

Functional Module

 

 

Slots

 

 

Slot Usage

2 power supply slots

 

 

1 common logic slot

 

 

12 identical slots for I/O (user) modules

Power

Module

100 – 240 VAC nominal, 50/60 Hz, maximum 160W

 

PS-LRS/230/115

 

 

Module PS-LRS/48

–48 VDC nominal, maximum 160W

 

Remote (Phantom)

LRS-PS-FEED standalone unit

 

Source

 

1-14 Technical Specifications

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Page 26
Image 26
RAD Data comm LRS-24 operation manual Technical Specifications, User Modules, Number