LRS-24Installation and Operation ManualAppendix D CM-2 Management Commands

 

Table D-3 DEF HUB Command Fields (Cont.)

 

 

 

Field Name

Description

Options

 

 

 

BURN IN MAC ADDRESS

Fctory MAC address used by BOOTP server to

 

 

declare the IP address of the CM-2.

 

BOOTP ON/OFF

Toggle to select BOOTP.

 

To maintain backwards compatibility (with any

 

LRS-12 version), set BOOTP ON/OFF to OFF.

 

Otherwise, BOOTP ON/OFF should be set ON.

 

In either case, BOOTP ON/OFF should be set to

 

OFF while setting the IP address.

ON– use BOOTP OFF–no BOOTP.

Default value: OFF

BOOTP TIME OUT

Maximum waiting time for a BOOTP response

1, 2, 3, 4, 6, 8, 10, 15, 20

 

 

seconds.

 

 

Default value: 10 seconds

 

 

 

BOOTP RETRIES

Number of times to retry sending a request for the

3, 4, 5, 10, 15, 20, 25, 30 times.

 

BOOTP server

Default value: 30 times

 

 

 

 

 

HUB IP MODE

 

SINGLE – only one IP address.

 

 

(The LRS-24 address is the CM-2

 

 

address.). CM-2 receives SMOD

 

 

message and transfers to it to the

 

 

SMOD modem after adjusting

 

 

the IP. The IP is resolved from

 

 

the community field. In this

 

 

mode, ping and Telnet cannot

 

 

be used directly on an SMOD;

 

 

only the CM-2 IP address is

 

 

relevant.

 

 

MULTIPLE – normal mode.

 

 

Every SMOD has its own IP

 

 

address and the CM-2 does not

 

 

interfere at the IP level. Every

 

 

SMOD IP is calculated by

 

 

adding the CM-2 IP address and

 

 

the SMOD slot number.

 

 

 

SERIAL LINE PROTOCOL

SLIP Protocol

RS232 – terminal

 

 

 

STATION CLOCK

Set clock for station

Internal

 

 

External – Square

 

 

Ext-AMI

 

 

 

Defining LRS-24 And CM-2 SNMP Agent Parameters

D-7

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Page 109
Image 109
RAD Data comm LRS-24 operation manual Table D-3 DEF HUB Command Fields, Bootp ON/OFF