LRS-24Installation and Operation Manual

 

Chapter 2

Installation and Setup

Connect Minor

Connect Major

Alarm Relay

Alarm Relay

 

JP9

 

 

 

 

JP7

JP6

JP10

JP11

 

 

 

 

JP8

JP7 JP6

JP9 JP8

JP10 JP11

Figure 2-13. Interface Module LRSI-F-2-CM2 with BNC Connectors, Internal Jumpers Table 2-9lists the functions of the jumpers located on the LRSI-F-2-CM2 module.

Table 2-9. LRSI-F-2-CM2 Interface Module Jumper Settings

Jumpers

Controls

Settings/Options

 

 

 

JP6, JP7, JP8

Major alarm relay connection

To use the major alarm relay, install

 

 

jumpers as shown in Figure 2-11or

 

 

Figure 2-13.

 

 

To disconnect the relay, remove the

 

 

jumpers (for storage, you may leave

 

 

the jumpers inserted over one pin).

 

 

JP9, JP10, JP11 Minor alarm relay connection

To use the minor alarm relay, install

 

 

jumpers as shown in Figure 2-11or

 

 

Figure 2-13.

To disconnect the relay, remove the jumpers.

Interfaces and Connections

2-23