Quick Start Guide

LRS-24Installation and Operation Manual

 

 

 

 

 

 

2.LRS-24 with CM-2 Module

This section contains the startup instructions for LRS-24 with the CM-2 module.

Power-On

To turn the power on:

1.Set the ON/OFF switches on the panels of the LRSI-PSP** modules to ON.

2.Supply the DC power, as applicable.

To supply external phantom feed voltages:

1.Turn on LRS-24.

2.Turn on the source (for example, LRS-PS-FEED).

Normal Indications

PS Module(s): All the indicators on the panel(s) of the PS module(s) must light in green to indicate proper operation.

CM-2 Module: The POWER indicator of the module must light. The TD and RD indicators may flash (or light steadily) when a management session is in progress.

Normally, the STAT/ADD display shows the two least significant digits of the management number assigned to LRS-24. For normal startup, a rotating red circle is displayed. However, if a problem is detected during the power-up self-test, you will see a flashing error code (E1 through E9).

Preliminary Configuration

Perform preliminary configuration on the LRS-24 hub (see Chapter 4).