LRS-24Installation and Operation ManualChapter 2 Installation and Setup

Table 2-3. Module CM-1 Jumper Settings

Jumpers

Description

Values

 

 

 

JP4, JP5, JP6,

Select the station clock interface in the

T1 interface (1544 kHz clock): Set jumper JP5 in

JP9, JP10,

STATION CLK connector of the

the T1-DSU position and jumpers JP9 and JP10 to

 

LRSI-F-CM1 interface module.

BAL.

 

 

Balanced E1 interface (2048 kHz clock): Set

 

 

jumper JP4 in the E1-BAL position, and jumpers JP9

 

 

and JP10 to BAL.

 

 

Unbalanced E1 interface (2048 kHz clock): Set

 

 

jumper JP6 in the E1-UBAL position, and jumpers

 

 

JP9 and JP10 to UBAL.

 

 

Default setting: Balanced E1 interface

 

 

 

LCODE, JP11

Selects the line code accepted by the

AMI—AMI line code: Use this selection for the T1

 

station clock interface in the STATION

interface.

 

CLK connector of the LRSI-F-CM1

HDB3—HDB3 line code: Use this selection for the

 

interface module.

 

E1 interfaces.

 

 

 

 

Default setting: HDB3

 

 

 

RLOOP, JP12

Controls the operating mode of the

ON: The station clock interface returns the

 

station clock interface in the STATION

regenerated clock signal toward the clock source.

 

CLK connector of the LRSI-F-CM1

OFF: The station clock interface does not return

 

interface module.

 

clock signal toward the clock source.

 

 

 

 

Unless your system has special requirements,

 

 

always set the jumper JP12 to ON.

 

 

Default setting: JP12 ON

 

 

 

STATCLK,

Selects the levels of the clock signal

SYS: Clock signal at G.703 levels regenerated from

JP14

provided by the CM-1 module as a

the STATION CLK connector.

 

station clock signal for the user modules

TTL: Clock signal at TTL levels, provided by a

 

installed in LRS-24.

 

dedicated line receiver.

 

 

 

 

Select the position best suited to the requirements

 

 

of the user modules installed in LRS-24: for

 

 

HTU-E1C module, always set the jumper JP14 to

 

 

SYS and the jumper JP15 to DIS.

 

 

Default setting: SYS

 

 

 

RCEN, JP15

Connects the supply voltage to the line

EN: Line receiver enabled. Always select this

 

receiver which provides a clock signal at

position when the jumper JP14 is set to TTL.

 

TTL levels when the jumper JP14 is set

DIS: Line receiver disabled. Always select this

 

to TTL.

 

position when the jumper JP14 is set to SYS.

 

 

 

 

Default setting: DIS

 

 

 

Installation and Setup

2-11

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Page 39
Image 39
RAD Data comm LRS-24 operation manual Module CM-1 Jumper Settings