Chapter 2 Installation and Setup

LRS-24Installation and Operation Manual

 

 

PS Module Installation

To install the first PS module:

1.Make sure that the POWER switches on the two LRSI-PS interface modules are set to OFF.

2.Insert the specified PS module in the PS-A slot, referring to the system installation plan in LRS-24 Module Slots, Chapter 1.

3.Fasten the PS module with the two screws.

4.If an additional redundant module is used, install it in the PS-B slot.

Note

 

You can install a redundant module in an operating enclosure without turning off

 

 

the enclosure power. After the module is installed, connect the power cable and set

 

the power switch located on the corresponding interface module to ON.

 

An AC and a DC PS module can be installed at the same time.

CM-1 Module

This section covers installation of the CM-1 module and of the associated interface module in an LRS-24 enclosure. The first part covers the installation of the CM-1 module. The second section covers the installation of the interface module for the CM-1 module: LRSI-F-CM1.

Front Panel

A typical front panel for the CM-1 module is shown in Figure 2-4.The functions of the components located on the front panel are listed in Table 2-2.

2-8

Installation and Setup