LRS-24Installation and Operation ManualAppendix A Connector Wiring

Table A-3. Pin Allocation for Management RS-232 Connector on

 

CM-1/CM-2 Modules

(Cont.)

 

 

 

Pin

Function

Direction

 

 

 

7

Request to Send (RTS)

Connected to pins 1, 8

 

 

 

8

Clear to Send (CTS)

Connected to pins 1, 7

 

 

 

9

Ring Indicator (RI)

N/A

 

 

 

A.4 Station CLK Connector – LRSI-F-CM2 Modules

The station clock interface located on the LRSI-F-CM2 modules are terminated in

a15-pin D-type female connector, designated STATION CLK, and wired in accordance with Table A-4.

The connector also includes the contacts of the major and minor alarm relays.

Table A-4. Pin Allocation for LRSI-F-CM2 Modules, Station Clk Connector

Pin

Function

 

 

1

Station Clock Transmit Output (tip)

 

 

2

Not Connected

 

 

3

Station Clock Receive Input (tip)

 

 

4, 5

Not Connected

 

 

6

Minor Alarm Relay – Normally Closed (NC) to pin 14

 

 

7

Major Alarm Relay – Normally Open (NO) relative to pin 8

 

 

8

Major Alarm Relay – Common Contact

 

 

9

Station Clock Transmit Output (ring)

 

 

10

Not Connected

 

 

11

Station Clock Receive Input (ring)

 

 

12

Not Connected

 

 

13

Minor Alarm Relay – Normally Open (NO) relative to pin 14

 

 

14

Minor Alarm Relay – Common Contact

 

 

15

Major Alarm Relay – Normally Closed (NC) to pin 8

 

 

Station CLK Connector – LRSI-F-CM2 Modules

A-3

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Page 87
Image 87
RAD Data comm LRS-24 operation manual Station CLK Connector LRSI-F-CM2 Modules, Cont