LRS-24Installation and Operation Manual

Chapter 4 Management via the CM-2 Module

 

 

To configure an SMOD-type module on the DSP HUB data form:

1.Follow the procedures described in the Installation and Operation Manual of the appropriate module.

2.Pay special attention to the configuration of the parameters of the internal SNMP agent of the module and its supervisory port parameters.

3.Before each command, type the node number in the format:

Node nn command <Enter>

nnstands for the node number of the desired module, with values 1 through 12, and command is the desired command string.

The prompt changes from CM2> to the module prompt.

Note If the prompt changes to PASSWORD>, this indicates that password protection is enabled on the addressed module. Enter the current password to proceed. If the password is not known, refer to the module Installation and Operation Manual for instructions.

To configure an IMOD-type module on the DSP HUB data form:

1.Refer to the module Installation and Operation Manual.

2.Enter the following sequence of commands: NODE nn DEF TST – to ensure no test is active.

NODE nn DEF OPR – to verify that you are in master mode. NODE nn DEF PRM – to configure the appropriate parameters. nn stands for the node number of the desired module, with values 1 through 12.

During this procedure, the prompt displayed by the terminal remains CM2>.

Configuration by SNMP Network Management Stations

After preliminary configuration, by means of the terminal, the network management station manages LRS-24. The basic preliminary parameters cannot be modified.

Transferring Control to the Supervision Terminal

When a network management station actively communicates with LRS-24, the supervision terminal can only be used to read status and configuration information. It cannot modify parameters.

Three minutes after communication between a network management station and the CM-2 module fails, the CM-2 module automatically changes its operation mode to management by terminal. When communication is restored, the CM-2 module automatically resumes being controlled by the network management station.

Supervision Terminal Operating Instructions

4-15