Press the [ENTER] button.
Use the [0][F]keys to input the first byte.

Edit mode (EDIT)

10Input the third and subsequent bytes in the same way.

11When you have finished inputting the message, use the keyboard to enter [F] and [7], specifying the ending status byte “F7”.

12Press the [ENTER] button.

13Specify the output port. (“Specifying the port” (p. 159))

14If you are making an assignment for a button, specify the button mode. (“Specifying the button mode” (p. 158))

For Advanced mode 2

7

8

9

The display will indicate “F-.”

Use the [6], [8], [A][C], [F] keys to specify the system message.

Press the [ENTER] button.

Specify the output port. (“Specifying the port” (p. 159))

For Advanced modes 3 or 4

7

8

9

The display will indicate “L--”.

Use the [0][F]keys of the keyboard to specify the number (decimal) of bytes you want to input.

*1 Reference

10Press the [ENTER] button.

11Input the second and subsequent bytes in the same way.

12After you have input the number of bytes you specified in step 7, the PCR-30/50/80 will check whether the messages you've input are indeed valid MIDI messages. If there is a problem, the display will indicate “ERR”.

In this case, you should press the [ENTER] button, which takes you back to step 7, where you can input the values over again.

*1 The -- area displays the currently set value. If it has not been set, the default setting will be displayed. Even if you change the type or mode 141 of the MIDI message that is assigned, the default setting will be displayed. This will be lit if the value is the same as the currently set value,

or will blink if the value is different.