Edit mode (EDIT)
13In the case of Advanced mode 4, specify the upper and lower limits.
14Specify the output port. (➔“Specifying the port” (p. 159))
15If you are making an assignment for a button, specify the button mode. (➔“Specifying the button mode” (p. 158))
Here are some examples of inputting various actual system exclusive messages.
●GM2 System OnF0 7E 7F 09 03 F7
Here’s how to assign a GM2 System On system exclusive message in Basic mode.
1.Press the [EDIT] button.
The display will indicate “EDT”.
2.Slightly move the controller to which you want to assign the system exclusive message. In the case of a button, press that button.
The display will indicate the number of the selected controller.
3.Confirm what’s indicated, and press the [ENTER] button.
4.Press the [SYSTEM Ex.] key. The display will indicate “SE0”.
5.Confirm what’s indicated, and press the [ENTER] button.
The display will indicate “F0”, which is the first byte (beginning status) of a system exclusive message. This cannot be changed. (This cannot be changed.)
6.Confirm what’s indicated, and press the [ENTER] button.
7.Use the [7] and [E] keys to input the second byte “7E”.
8.Confirm what’s indicated, and press the [ENTER] button.
9.Use the [7] and [F] keys to input the third byte “7F”.
10.Confirm what’s indicated, and press the [ENTER] button. Input the fourth and fifth bytes in the same way.
11.Finally, use the [F] and [7] keys to input the ending status byte “F7”.
12.Confirm what’s indicated, and press the [ENTER] button.
13.Specify the output port. (➔“Specifying the port” (p. 159))
14.If you are making an assignment for a button, specify the button mode. (➔“Specifying the button mode” (p. 158))
The GM2 System On message has now been assigned.
142