1GENERAL 1999.9.15 12:46 PM 페이지12

NX-SERIESHYBRID KEY SYSTEM

GENERAL DESCRIPTION SECTION

5. SPECIFICATIONS

5.1 ELECTRICAL SPECIFICATIONS

AC INPUT

110/220 VAC, 50/60 Hz

 

POWER

NX-308

50 WATTS MAX

CONSUMPTION

NX-820

55 WATTS MAX

 

NX-1232

80 WATTS MAX

MAX CURRENT

NX-308

0.22 AMP

DRAW AT 220 VAC

NX-820

0.29 AMP

 

NX-1232

0.36 AMP

RING GENERATOR

AC 80 Vrms, 25 Hz

 

BATTERY BACKUP

24 VDC, 6 to 26Ah

 

SUPPLY

 

 

 

 

 

 

5.2 DIMENSIONS AND WEIGHTS

NX-308

530mm(H) x 348mm(W) x 102mm(D),

4.9Kg

KEY SERVICE UNIT NX-820

530mm(H) x 412mm(W) x 140mm(D),

8.9Kg

NX-1232

530mm(H) x 412mm(W) x 140mm(D),

8.9Kg

KEYSET

214mm(H) x 206mm(W) x 150mm(D),

1.1Kg

AOM

214mm(H) x 133mm(W) x 150mm(D),

0.4Kg

DOOR PHONE

158mm(H) x 89mm(W) x 41mm(D),

0.23Kg

 

 

 

5.3 ENVIRONMENTAL LIMITATIONS

OPERATING TEMPERATURES

0- 45(18- 25recommended)

OPERATING HUMIDITY

10% - 90% (non-condensing)

 

 

5.4 CABLE REQUIREMENTS

ELECTRONIC SET

2 pair twisted, Max. 400 m (24 AWG)

SINGLE LINE TELEPHONE

1 pair twisted, Max. 1 km (24 AWG)

DOOR PHONE

1 pair twisted, Max. 100 m (24 AWG)

4 OPX B’D

1 pair twisted, Max. 2Km (24 AWG)

 

 

1 - 8

Page 17
Image 17
Samsung NX-308 Electrical Specifications, Dimensions and Weights, Environmental Limitations, Cable Requirements