4Programming 1999.9.15 12:42 PM 페이지19

NX-SERIESHYBRID KEY SYSTEM

PROGRAMMING SECTION

 

 

MMC 16

KEY EXTENDER

This MMC is used to view the programmable keys assigned to a keyset station.

It also allows the system administrator to assign key extenders to some keys to make a feature key more specific. The feature keys accept extenders are:

FEATURE KEY

EXTENDER

FWE

External Call Forward(00~99)

SPEED

Dial (00~99)

VAC

Vacant messages (01~20)

PAG

Page (0~5,)

DOR

Door & Door Lock control (1~4)

EXC

Boss and Secretary (1~2)

DPC

Direct Pickup (station / trunk-line number)

GPC

Group Pickup (0~9)

PROCEDURE

LCD DISPLAY

1. Press [TRANSFER] and dial 16

 

 

 

2. Using [VOLUME (-)or (+)], select a station (e.g. 202)

3.Press [REDIAL] or [FLASH] to select a feature key button (e.g. 22)

OR

Press the button you want to extend if it is already programmed.

4.Dial the extender according to the above table. A previous extender will be overwritten

To clear the extended key, press [HOLD]

5.Press [TRANSFER] to save and exit

DEFAULT DATA

Key extender is set to STATION KEY PROGRAMMING (MMC 72) data.

RELATED MMC

MMC 71 SYSTEM KEY PROGRAMMING

MMC 72 STATION KEY PROGRAMMING

Page 88