4Programming 1999.9.15 12:44 PM 페이지68
PROGRAMMING SECTION | |
|
|
MMC 80 | SYSTEM I/O PARAMETERS |
This MMC provides a means of setting parameters for the serial I/O ports to work with SMDR and Remote MMC. Programming is accomplished easily with the tables below to customize either I/O port.
PARAMETER | OPTIONS |
TYPE OF SERVICE | SMDR, REMOTE, TRAFFIC |
REMOTE STN | REMOTE only |
BAUD RATE | 300, 600, 1200, 2400, 4800, 9600 BPS |
CHARACTER LENGTH | 7 BIT, 8 BIT |
PARITY | NONE, EVEN, ODD |
STOP BIT | 1 |
PROCEDURE | LCD DISPLAY |
1. Press [TRANSFER] and dial 80 |
|
Display Shows |
|
|
|
2.Press [VOLUME
3. Press [REDIAL] or [FLASH] to select the parameters
4. Press [MUTE] or [MESSAGE] to select data
5.Press [TRANSFER] to save and exit
DEFAULT DATA
COM1 | : 9600 8 NONE |
COM2 | : 9600 8 NONE |
COM1 | : XON OFF : ON |
COM2 | : XON OFF : ON |
SMDR | : COM1 |
TRAFFIC | : COM1 |
REMOTE | : COM2 STN : NONE |
NOTE: “XON OFF” means whether the system checks the CTS pin of the serial port or not ‘REMOTE STN’ means the port displaying the Remote MMC procedure.
RELATED MMC
NONE