4Programming 1999.9.15 12:44 PM 페이지68

NX-SERIESHYBRID KEY SYSTEM

PROGRAMMING SECTION

 

 

MMC 80

SYSTEM I/O PARAMETERS

This MMC provides a means of setting parameters for the serial I/O ports to work with SMDR and Remote MMC. Programming is accomplished easily with the tables below to customize either I/O port.

PARAMETER

OPTIONS

TYPE OF SERVICE

SMDR, REMOTE, TRAFFIC

REMOTE STN

REMOTE only

BAUD RATE

300, 600, 1200, 2400, 4800, 9600 BPS

CHARACTER LENGTH

7 BIT, 8 BIT

PARITY

NONE, EVEN, ODD

STOP BIT

1

PROCEDURE

LCD DISPLAY

1. Press [TRANSFER] and dial 80

 

Display Shows

 

 

 

2.Press [VOLUME (-)or (+)] to select the serial port (COM1, COM2) COM1 and COM2 may be found on SMDR/R-MMC card. COM1 is SMDR and COM2 is R-MMC. COM1 is used for SMDR or TRAFFIC port and COM 2 is used for Remote Programming.

3. Press [REDIAL] or [FLASH] to select the parameters

4. Press [MUTE] or [MESSAGE] to select data

5.Press [TRANSFER] to save and exit

DEFAULT DATA

COM1

: 9600 8 NONE

COM2

: 9600 8 NONE

COM1

: XON OFF : ON

COM2

: XON OFF : ON

SMDR

: COM1

TRAFFIC

: COM1

REMOTE

: COM2 STN : NONE

NOTE: “XON OFF” means whether the system checks the CTS pin of the serial port or not ‘REMOTE STN’ means the port displaying the Remote MMC procedure.

RELATED MMC

NONE

Page 137
Image 137
Samsung NX-308 technical manual System I/O Parameters, Parameter Options