2INSTALL 1999.9.15 12:45 PM 페이지26
6.2.1 NX-308 - Related Switch Location (FIGURE 6-3)
To connect the single line telephone to the any station from #2 to #8 of basic
KSU, the related DIP switches should be set as follows.
Station No. |
| Releated DIP Switches |
| ||||
|
|
| ❶ | ❷ | ❸ |
| ❹ |
|
|
|
|
|
|
| |
STN 2 |
| SW 1 | OFF | OFF | ON |
| ON |
STN 3 |
| SW 2 | OFF | OFF | ON |
| ON |
STN 4 |
| SW 3 | OFF | OFF | ON |
| ON |
STN 5 |
| SW 4 | OFF | OFF | ON |
| ON |
STN 6 |
| SW 5 | OFF | OFF | ON |
| ON |
STN 7 |
| SW 6 | OFF | OFF | ON |
| ON |
STN 8 |
| SW 7 | OFF | OFF | ON |
| ON |
|
|
|
|
|
|
|
|
Setting
S
6.2.2 NX-820
To connect a
6.2.3 NX-1232 - Related Switch Location (FIGURE 6-5)
To connect a single line telephone to any station from #1 to #16 of basic KSU.
Station No. |
| Releated DIP Switches |
| ||||
|
|
| ❶ | ❷ | ❸ |
| ❹ |
|
|
|
|
|
|
| |
STN 1 |
| SW 8 | OFF | OFF | ON |
| ON |
STN 2 |
| SW 7 | OFF | OFF | ON |
| ON |
STN 3 |
| SW 6 | OFF | OFF | ON |
| ON |
STN 4 |
| SW 5 | OFF | OFF | ON |
| ON |
STN 5 |
| SW 4 | OFF | OFF | ON |
| ON |
STN 6 |
| SW 3 | OFF | OFF | ON |
| ON |
STN 7 |
| SW 2 | OFF | OFF | ON |
| ON |
STN 8 |
| SW 1 | OFF | OFF | ON |
| ON |
|
|
|
|
|
|
|
|
Setting
S
2 - 22