4Programming 1999.9.15 12:43 PM 페이지50

NX-SERIESHYBRID KEY SYSTEM

PROGRAMMING SECTION

 

 

MMC 51

TONE/RING CADENCE

This MMC is used to customize the tone cadence on a system-wide basis to any one of the eight available selections.

Call Technical Support before changing any cadences, as some systems may require default settings.

PROCEDURE

LCD DISPLAY

1. Press [TRANSFER] and dial 51 Display shows

2. Press [VOLUME (-)or (+)] to select a tone

3. Press [MUTE] or [MESSAGE] to set dial tone to continuous or interrupted tone

Interrupt tone default data is: 1000 0250 1000 0250 ms

4. Dial new interrupt value for interrupt time, (ON/OFF/ON/OFF) in 50 ms steps.

Each field is 3 digits (UNIT: 10 ms)

(e.g. 100/030/100/030 = 1000 ms [100×10] 'ON' and 300 ms [030×10] 'OFF' time)

5. Press [TRANSFER] to save and exit

DEFAULT DATA

TONE NAME

DISPLAY

DATA

 

DIAL TONE

(DT)

CONTINUOUS TONE

RING BACK TONE

(RBT)

1000 2000

1000 2000 ms

BUSY TONE

(BST)

0500 0500

0500 0500 ms

TRSF TONE

(TT)

0200 0200

0200 0200 ms

ERROR TONE

(ERT)

0500 0250

0500 0250 ms

CO LINE RING

(COR)

1000 3000

1000 3000 ms

STATION RING

(STR)

0400 0200

0400 3000 ms

RELATED MMC

NONE