10. Indoor Unit Control of the Electronic Control Valve

W-2WAY ECO-i SYSTEM Control Functions

10-2. Special Control

1

Control

4-way valve adjustment control

Reverse cycle defrost control

Outdoor cycle defrost control

System refrigerant oil recovery control

Operating

Subject indoor units

Position of electronic control valve

mode

 

 

 

 

Cooling

 

All indoor units

Fixed pulse for cooling, according to indoor unit

 

capacity

 

 

 

 

 

 

 

 

 

Heating

 

All indoor units

250

 

 

 

Stopped

Cooling control, according to indoor unit capacity

 

 

 

Fan

Cooling control, according to indoor unit capacity

Heating

Heating

 

Thermostat

Fixed pulse for heating, according to indoor unit

 

ON

capacity

 

 

 

 

 

 

 

 

 

 

Thermostat

Heating control, according to indoor unit capacity

 

 

 

OFF

However, position is 20 pulses for Type D.

 

 

 

 

 

 

 

 

Stopped

60 pulses

 

 

 

Fan

60 pulses

Cooling/

Heating

 

Thermostat

60 pulses

heating

 

ON

 

60 pulses

 

 

 

Thermostat

 

 

 

 

OFF

 

 

 

 

 

 

Cooling

 

All indoor units

Fixed pulse for cooling, according to indoor unit

 

capacity

 

 

 

 

Heating

 

All indoor units

250