W-2WAY ECO-i SYSTEM

2. Detailed Settings Function

Remote Controller Functions

 

 

 

 

 

Item code

Item

 

 

Setting data

No.

 

Description

 

 

 

 

 

 

 

 

 

 

 

DC fan tap operating

Purpose

 

 

 

mode

 

 

 

 

 

 

0000

Standard

Standard (setting at shipment)

 

 

 

High ceiling use

High ceiling setting 1 (with standard panel)

 

 

0001

For low

Ultra long-life filter, oil guard panel, ammonia deodorizing

 

Fan tap setting

 

static-pressure filter

filter, optical regenerative deodorizing filter

 

(Fan tap change in order

 

High ceiling use

High ceiling setting 2 (with standard panel)

 

to prevent drop in air

 

 

(Antibacterial) high-performance filter (90%)

 

discharge caused by

 

For low

(Antibacterial) high-performance filter (65%)

 

filter installation)

0003

static-pressure filter

Air-cleaning unit, air-cleaning unit + optical regenerative

 

 

 

 

deodorizing filter, deodorant (activated charcoal) filter

 

 

 

For air-blocking

For 3-way discharge, when discharge duct is connected

 

 

 

material

 

 

 

 

 

 

0006

For air-blocking

For 2-way discharge

 

 

material

 

 

 

 

 

 

0000

No humidifier output

 

 

 

0001

1 sec.

 

 

Humidifier ON time

0002

2 sec.

 

 

 

 

 

 

(ON time per 60

 

 

 

 

seconds)

 

 

 

 

0058

58 sec.

 

 

 

 

 

 

0059

59 sec.

 

 

 

0060

Continuously ON

 

 

Repeat timer switching

0000

Function disabled

 

 

 

 

 

 

0001

Function enabled

 

 

 

 

 

 

 

 

 

 

Timer function change

0000

Function disabled

 

 

prohibit

0001

Function enabled

 

 

Smudging control

0000

No smudging control

 

 

 

 

 

 